7045-SW4
Special Features - Initial Orders
- POWER:
- (#6233) - DC Power Converter Assembly, 7045/SW4
Special Features - Plant and/or Field Installable
- ADAPTERS:
- (#6433) - Switch Port Connection Card, Copper
- (#6436) - Switch Port Connection Card, Optical
- CABLES:
- (#3161) - Switch Cable, 1.2 meter Copper
- (#3166) - Switch Cable, 3 meter Copper
- (#3167) - Switch Cable, 10 meter Copper
- (#3256) - Switch Cables, 20 meter Optical
- (#3257) - Switch Cables, 40 meter Optical
- (#3800) - Power Cable Group, Left, Drawer Position #4609
- (#3801) - Power Cable Group, Left, Drawer Position #4605
- (#3802) - Power Cable Group, Left, Drawer Position #4601
- (#3803) - Power Cable Group, Left, Drawer Position #4619
- (#3804) - Power Cable Group, Left, Drawer Position #4623
- (#3805) - Power Cable Group, Left, Drawer Position #4627
- (#3806) - Power Cable Group, Left, Drawer Position #4631
- (#3807) - Power Cable Group, Left, Drawer Position #4613
- (#3810) - Power Cable Group, Right, Drawer Position #4609
- (#3811) - Power Cable Group, Right, Drawer Position #4605
- (#3812) - Power Cable Group, Right, Drawer Position #4601
- (#3813) - Power Cable Group, Right, Drawer Position #4619
- (#3814) - Power Cable Group, Right, Drawer Position #4623
- (#3815) - Power Cable Group, Right, Drawer Position #4627
- (#3816) - Power Cable Group, Right, Drawer Position #4631
- (#3817) - Power Cable Group, Right, Drawer Position #4613
- (#6123) - I/O Drawer Attachment Cable Group, Drawer Position #4601
- (#6125) - I/O Drawer Attachment Cable Group, Drawer Position #4401
- (#6126) - I/O Drawer Attachment Cable Group, Drawer Position #4405
- (#6127) - I/O Drawer Attachment Cable Group, Drawer Position #4409
- (#6128) - I/O Drawer Attachment Cable Group, Drawer Position #4413
- (#6129) - I/O Drawer Attachment Cable Group, Drawer Position #4419
- (#7842) - Drawer Attachment Cable Group, Drawer Position #4439
- (#7849) - Drawer Attachment Cable Group, Drawer Position #4423
- (#7850) - Drawer Attachment Cable Group, Drawer Position #4427
- (#7851) - Drawer Attachment Cable Group, Drawer Position #4431
- (#7852) - Drawer Attachment Cable Group, Drawer Position #4435
Feature Descriptions
- (#3161) Switch Cable, 1.2 meter Copper
- The Switch Cable, 1.2 meter Copper, is used within the pSeries High Performance Switch (HPS) network to enable copper connections between the switch network interface (SNI) features in the p655 to the switch port connection card within the HPS for p655 servers in EIA locations 5, 9 and 13. It is also used for NSB to ISB switch connections when the NSBs and ISBs are in the same multi-switch rack.
- Attributes provided: Switch Cable, 1.2 meter Copper
- Attributes required: None
- For 7045-SW4: (#3161)
- Minimum required: 0
- Maximum allowed: No Max (Initial order maximum: No Max)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3166) Switch Cable, 3 meter Copper
- The Switch Cable, 3 meter Copper, is used within the pSeries High Performance Switch (HPS) network to enable copper connections between the switch network interface (SNI) features in the p690 or p655 to the switch port connection card within the HPS.
- Attributes provided: Switch Cable, 3 meter Copper
- Attributes required: None
- For 7045-SW4: (#3166)
- Minimum required: 0
- Maximum allowed: No Max (Initial order maximum: No Max)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3167) Switch Cable, 10 meter Copper
- The Switch Cable, 10 meter Copper, is used within the pSeries High Performance Switch (HPS) network to enable copper connections between the switch network interface (SNI) features in the p690 or p655 to the switch port connection card within the HPS. It is used when the switch is in a different rack than the p690 or p655. #3167 is also used for switch to switch connections between Node Switch Boards (NSB's) or between NSB's and Intermediate Switch Boards (ISB's).
- Attributes provided: Switch Cable, 10 meter Copper
- Attributes required: None
- For 7045-SW4: (#3167)
- Minimum required: 0
- Maximum allowed: No Max (Initial order maximum: No Max)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3256) Switch Cables, 20 meter Optical
- The Switch Cables, 20 meter Optical, are used within the pSeries High Performance Switch (HPS) network to enable optic connections between the switch port connection card (optical) within the HPS for switch to switch applications. #3256 delivers an optical cable pair consisting of a tranmitter cable and receiver cable.
- Attributes provided: Switch Cables, 20 meter Optical
- Attributes required: None
- For 7045-SW4: (#3256)
- Minimum required: 0
- Maximum allowed: No Max (Initial order maximum: No Max)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3257) Switch Cables, 40 meter Optical
- The Switch Cables, 40 meter Optical, are used within the pSeries High Performance Switch (HPS) network to enable optic connections between the switch port connection card (optical) within the HPS for switch to switch applications. #3257 delivers an optical cable pair consisting of a tranmitter cable and receiver cable.
- Attributes provided: Switch Cables, 40 meter Optical
- Attributes required: None
- For 7045-SW4: (#3257)
- Minimum required: 0
- Maximum allowed: No Max (Initial order maximum: No Max)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3800) Power Cable Group, Left, Drawer Position #4609
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 9U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4609
- For 7045-SW4: (#3800)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3801) Power Cable Group, Left, Drawer Position #4605
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 5U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4605
- For 7045-SW4: (#3801)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3802) Power Cable Group, Left, Drawer Position #4601
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 1U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4601
- For 7045-SW4: (#3802)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- Note: #3802 is used when the 7045-SW4 is located in the 7040-W42 rack.
- (#3803) Power Cable Group, Left, Drawer Position #4619
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 19U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4619
- For 7045-SW4: (#3803)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3804) Power Cable Group, Left, Drawer Position #4623
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 23U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4623
- For 7045-SW4: (#3804)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3805) Power Cable Group, Left, Drawer Position #4627
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 27U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4627
- For 7045-SW4: (#3805)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3806) Power Cable Group, Left, Drawer Position #4631
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 31U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4631
- For 7045-SW4: (#3806)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3807) Power Cable Group, Left, Drawer Position #4613
- This feature provides redundant power cabling for the left side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 13U location of the primary system rack.
- Attributes provided: Redundant Left Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4613
- For 7045-SW4: (#3807)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3810) Power Cable Group, Right, Drawer Position #4609
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 9U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4609
- For 7045-SW4: (#3810)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3811) Power Cable Group, Right, Drawer Position #4605
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 5U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4605
- For 7045-SW4: (#3811)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3812) Power Cable Group, Right, Drawer Position #4601
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 1U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4601
- For 7045-SW4: (#3812)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- Note: #3812 is used when the 7045-SW4 is located in the 7040-W42 rack.
- (#3813) Power Cable Group, Right, Drawer Position #4619
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 19U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4619
- For 7045-SW4: (#3813)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3814) Power Cable Group, Right, Drawer Position #4623
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 23U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4623
- For 7045-SW4: (#3814)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3815) Power Cable Group, Right, Drawer Position #4627
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 27U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4627
- For 7045-SW4: (#3815)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3816) Power Cable Group, Right, Drawer Position #4631
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 31U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4631
- For 7045-SW4: (#3816)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#3817) Power Cable Group, Right, Drawer Position #4613
- This feature provides redundant power cabling for the right side of a drawer (as viewed from the front of the rack) with the bottom of the drawer positioned at the 13U location of the primary system rack.
- Attributes provided: Redundant Right Side Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4613
- For 7045-SW4: (#3817)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4401) Drawer Placement Indicator, 1U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 1U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4401)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4405) Drawer Placement Indicator, 5U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 5U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4405)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4409) Drawer Placement Indicator, 9U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 9U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4409)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4413) Drawer Placement Indicator, 13U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 13U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4413)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4419) Drawer Placement Indicator, 19U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 19U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4419)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4423) Drawer Placement Indicator, 23U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 23U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4423)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4427) Drawer Placement Indicator, 27U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 27U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4427)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4431) Drawer Placement Indicator, 31U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 31U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4431)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4435) Drawer Placement Indicator, 35U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 35U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4435)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4439) Drawer Placement Indicator, 39U Position, Expansion Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 39U position of an expansion rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4439)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4601) Drawer Placement Indicator, 1U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 1U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4601)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4605) Drawer Placement Indicator, 5U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 5U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4605)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4609) Drawer Placement Indicator, 9U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 9U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4609)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4613) Drawer Placement Indicator, 13U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 13U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4613)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4619) Drawer Placement Indicator, 19U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 19U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4619)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4623) Drawer Placement Indicator, 23U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 23U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4623)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4627) Drawer Placement Indicator, 27U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 27U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4627)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4631) Drawer Placement Indicator, 31U Position, Primary Rack
- This drawer placement indicator specifies that the bottom of a drawer should be positioned at the 31U position of the primary system rack.
- Attributes provided: Drawer position indicator in rack
- Attributes required: Available rack space for the drawer
- For 7045-SW4: (#4631)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4651) Rack Indicator, Rack #1
- This indicator is used to specify the first rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the first rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4651)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4652) Rack Indicator, Rack #2
- This indicator is used to specify the second rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the second rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4652)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4653) Rack Indicator, Rack #3
- This indicator is used to specify the third rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the third rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4653)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4654) Rack Indicator, Rack #4
- This indicator is used to specify the fourth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fourth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4654)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4655) Rack Indicator, Rack #5
- This indicator is used to specify the fifth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fifth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4655)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4656) Rack Indicator, Rack #6
- This indicator is used to specify the sixth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the sixth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4656)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4657) Rack Indicator, Rack #7
- This indicator is used to specify the seventh rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the seventh rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4657)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4658) Rack Indicator, Rack #8
- This indicator is used to specify the eighth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the eighth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4658)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4659) Rack Indicator, Rack #9
- This indicator is used to specify the ninth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the ninth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4659)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4660) Rack Indicator, Rack #10
- This indicator is used to specify the tenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the tenth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4660)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4661) Rack Indicator, Rack #11
- This indicator is used to specify the eleventh rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the eleventh rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4661)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4662) Rack Indicator, Rack #12
- This indicator is used to specify the twelfth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the twelfth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4662)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4663) Rack Indicator, Rack #13
- This indicator is used to specify the thirteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the thirteenth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4663)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4664) Rack Indicator, Rack #14
- This indicator is used to specify the fourteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fourteenth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4664)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4665) Rack Indicator, Rack #15
- This indicator is used to specify the fifteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fifteenth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4665)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#4666) Rack Indicator, Rack #16
- This indicator is used to specify the sixteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the sixteenth rack of a multi rack complex.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 7045-SW4: (#4666)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6123) I/O Drawer Attachment Cable Group, Drawer Position #4601
- This feature provides redundant power cabling for an I/O drawer with the bottom of the drawer positioned at the 1U location of the primary system rack.
- Attributes provided: Redundant I/O Drawer Power Cables
- Attributes required: I/O Drawer with Placement Feature #4601
- For 7045-SW4: (#6123)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- Note: #6123 is used when the 7045-SW4 is located in the 7040-61R rack.
- (#6125) I/O Drawer Attachment Cable Group, Drawer Position #4401
- This feature provides redundant power cabling for an I/O drawer with the bottom of the drawer positioned at the 1U location of the expansion rack.
- Attributes provided: Redundant I/O Drawer Power Cables
- Attributes required: I/O Drawer with Placement Feature #4401
- For 7045-SW4: (#6125)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6126) I/O Drawer Attachment Cable Group, Drawer Position #4405
- This feature provides redundant power cabling for an I/O drawer with the bottom of the drawer positioned at the 5U location of the expansion rack.
- Attributes provided: Redundant I/O Drawer Power Cables
- Attributes required: I/O Drawer with Placement Feature #4405
- For 7045-SW4: (#6126)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6127) I/O Drawer Attachment Cable Group, Drawer Position #4409
- This feature provides redundant power cabling for an I/O drawer with the bottom of the drawer positioned at the 9U location of the expansion rack.
- Attributes provided: Redundant I/O Drawer Power Cables
- Attributes required: I/O Drawer with Placement Feature #4409
- For 7045-SW4: (#6127)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6128) I/O Drawer Attachment Cable Group, Drawer Position #4413
- This feature provides redundant power cabling for an I/O drawer with the bottom of the drawer positioned at the 13U location of the expansion rack.
- Attributes provided: Redundant I/O Drawer Power Cables
- Attributes required: I/O Drawer with Placement Feature #4413
- For 7045-SW4: (#6128)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6129) I/O Drawer Attachment Cable Group, Drawer Position #4419
- This feature provides redundant power cabling for an I/O drawer with the bottom of the drawer positioned at the 19U location of the expansion rack.
- Attributes provided: Redundant I/O Drawer Power Cables
- Attributes required: I/O Drawer with Placement Feature #4419
- For 7045-SW4: (#6129)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6233) DC Power Converter Assembly, 7045/SW4
- This feature converts power from the bulk power assembly to the voltage levels required within the HPS. Two (#6233) Power Converters are required per HPS.
- Attributes provided: HPS Power Converter
- Attributes required: 7045-SW4 High Performance Switch
- For 7045-SW4: (#6233)
- Minimum required: 2
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: Does not apply
- Return parts MES: Does not apply
- (#6433) Switch Port Connection Card, Copper
- The Switch Port Connection Card, Copper, is used within the pSeries High Performance Switch (HPS) to enable copper switch network interface (SNI) ports for connection to SNI features in the p690 or p655, and for connection of cables from switch to switch.
- Attributes provided: Switch Port Connection Card, Copper
- Attributes required: Unused Switch Port Connection Card slot.
- For 7045-SW4: (#6433)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6435) Switch Port Connection Card, Blank
- The Switch Port Connection Card, Blank, is used within the pSeries High Performance Switch (HPS) for unused Switch Port Connection Card slots.
- Attributes provided: Blank Switch Port Connection Card
- Attributes required: Unused Switch Port Connection Card slot.
- For 7045-SW4: (#6435)
- Minimum required: 0
- Maximum allowed: 15 (Initial order maximum: 15)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#6436) Switch Port Connection Card, Optical
- The Switch Port Connection Card, Optical, is used within the pSeries High Performance Switch (HPS) to enable optic switch ports for connection of optic cables from switch to switch. #6436 provides two optic ports, each port consisting of a transmitter and receiver.
- Attributes provided: Switch Port Connection Card, Optical
- Attributes required: Unused Switch Port Connection Card slot.
- For 7045-SW4: (#6436)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#7842) Drawer Attachment Cable Group, Drawer Position #4439
- This feature provides redundant power cabling for a drawer with the bottom of the drawer positioned at the 39U location of the expansion rack.
- Attributes provided: Redundant Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4439
- For 7045-SW4: (#7842)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#7849) Drawer Attachment Cable Group, Drawer Position #4423
- This feature provides redundant power cabling for a drawer with the bottom of the drawer positioned at the 23U location of the expansion rack.
- Attributes provided: Redundant Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4423
- For 7045-SW4: (#7849)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#7850) Drawer Attachment Cable Group, Drawer Position #4427
- This feature provides redundant power cabling for a drawer with the bottom of the drawer positioned at the 27U location of the expansion rack.
- Attributes provided: Redundant Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4427
- For 7045-SW4: (#7850)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#7851) Drawer Attachment Cable Group, Drawer Position #4431
- This feature provides redundant power cabling for a drawer with the bottom of the drawer positioned at the 31U location of the expansion rack.
- Attributes provided: Redundant Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4431
- For 7045-SW4: (#7851)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#7852) Drawer Attachment Cable Group, Drawer Position #4435
- This feature provides redundant power cabling for a drawer with the bottom of the drawer positioned at the 35U location of the expansion rack.
- Attributes provided: Redundant Drawer Power Cables
- Attributes required: Drawer with Placement Feature #4435
- For 7045-SW4: (#7852)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#9047) Node Switch Board Indicator
- Indicator of "Node Switch Board" (NSB) designation for the High Performance Switch, 7045-SW4. An NSB connects to the Switch Network Interface Links (SNI) in a p690 or p655 to the HPS. It can also connect to other HPS's for network scalability.
- Attributes provided: Indicator of NSB for 7045-SW4.
- Attributes required: 7045-SW4
- For 7045-SW4: (#9047)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#9049) Intermediate Switch Board Indicator
- Indicator of "Intermediate Switch Board" (ISB) designation for the High Performance Switch, 7045-SW4. An ISB connects Node Switch Boards (NSB) together to form the HPS network in larger configurations for scalability and bandwidth.
- Attributes provided: Indicator of ISB for 7045-SW4.
- Attributes required: 7045-SW4
- For 7045-SW4: (#9049)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
- (#9300) Language Group Specify - US English
- English language group for nomenclature and standard publications.
- Attributes provided: None
- Attributes required: None
- For 7045-SW4: (#9300)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: Does not apply
- Return parts MES: Does not apply
|
|
|
|
|